Home>Peristaltic Pumps>Filling System>Microliter Peristaltic Pump-MLP Series

Microliter Peristaltic Pump-MLP Series

Lead Fluid MLP series products are mainly used for high-precision filling of various aqueous solutions, filling range 1μl~10ml. It has the advantages of high accuracy, high repeatability, high efficiency, high cleanliness, maintenance friendly and simple operation. It can be used manually and automatically.

Flow: 1uL-10mL
Max: 16 Channels
Category:

Description

Function and Feature

High filling accuracy,the error is less than ±0.2%.
Modular design,easy to expand,multiple pumps can be cascaded to form a multi-channel filling system.
The man-machine interface directly input liquid volume parameters, easy to operate.
High-precision servo motor drive,large torque,free-maintenance.
Rotary pressure tube structure, high efficiency, small volume.
The pump tube is low in loss, the continuous service life up to 700 hours, 12 hours attenuation rate<1%, simple maintenance.
Suction back function,zero dripping,instant shutdown.
High clean pipeline, easy to disassemble, easy to clean and sterilize, support CIP and SIP.
It can be operated manually or used with an automatic production line.

Technical Parameters

Filling Range1μl~10ml
Channel1(Single),up to 16 channels cascade are supported
Filling Time0.01~99.99S
Interval Time0.01~99.99S
Filling Times0(Infinite loop)~9999
TubingID 0.5~9.6mm
Display7 inch HD color touch screen
External Control SignalDry contact start signal, lack of bottle filling stop signal, feedback signal
CommunicationRS485,MODBUS commnunication protocol
PowerSingle channel<60W
Power SupplyAC100~240V,50/60Hz
DimensionReference size drawing

Feature Comparision

Compared with Traditional Peristaltic Pump

MLP Peristaltic Pump
Traditional Peristaltic Pump
Filling Accuracy
high accuracy,high repeatability, filling10μl error<±0.2μl,100ul error<±1μl, 10ml error<±0.4%
not suitable for filling less than 100ul,200μl error<±3μl, 10ml error<±1%
Filling Efficiency
high efficiency,productivity up to 60 bottles/min
average efficiency,productivity<40 bottles/min
Attenuation
12 hours continuous operation,attenuation<1%,work one day without calibration
12 H continuous operation,attentuation>5%, need to calibrate every 2 H
Tube Life
continuous operation,service life>700 hours
fail after 70-100 hours of continuous operation
Pulsation
no pulse,small impact,no splash
large pulse, easy to splash

Compared with Plunger Pump

MLP Peristaltic Pump
Plunger Pump
Cleanliness
no dead volume,no effusion,material only contact with clean pipeline,no pollution
dead volume,effusion,material contact with the pump head cavity
Ease of Use
filling different material,only replace the pipeline to avoid cross contamination, low cost,simple maintenance
One pump can only fill one material, complicated maintenance
Universality
the material may contain particles such as magnetic beads
material must be clean and free of impurities
Dripping
retractable without dripping
easy to drip
Cavity Shedding
low extrusion strength,no mechanical friction,smooth cavity wall without shedding
continuous mechanical friction,the cavity is easy to fall off particles

 

Filling Accuracy and Efficiency

MLP500

Filling Range
Filling Time
Error Value
Accuracy Error
12 Hours Attenuation Rate
1μl
0.01~0.02
±0.1μL
<±10%
<1%
5μl
0.09~0.18s1
±0.1μL
<±2%
10μl
0.18~0.36
±0.1μL
<±1%
0.09~0.18
±0.2μL
<±2%
20μl
0.18~0.36
±0.2μL
<±0.5%
50μl
0.22~0.44
±0.5μL
<±1%
100μl
0.2~0.4
±1μL
<±1%
200μl
0.17~0.35
±2μL
<±1%
300μl
0.27~0.541
±2μL
<±0.6%
0.13~0.27
±4μL
<±1.3%
500μl
0.23~0.46
±4μL
<±0.8%

MLP3000

Filling Range
Filling Time
Error Value
Accuracy Error
12 Hours Attenuation Rate
1μl
0.01~0.02
±0.1μL
<±10%
<1%
5μl
0.04~0.12
±0.1μL
<±2%
10μl
0.09~0.23
±0.1μL
<±1%
20μl
0.18~0.46
±0.1μL
<±0.5%
0.1~0.24
±0.2μL
<±1%
50μl
0.25~0.6
±0.2μL
<±0.4%
0.08~0.2
±0.5μL
<±1%
100μl
0.16~0.4
±0.5μL
<±0.5%
0.13~0.3
1μL
<±1%
200μl
0.26~0.6
±1μL
<±0.5%
0.1~0.25
±2μL
<±1%
300μl
0.15~0.35
±2μL
<±0.6%
0.1~0.22
±4μL
<±1.6%
500μl
0.25~0.6
±2μL
<±0.4%
0.16~0.35
±4μL
<±0.8%
800μl
0.11~0.23
±8μL
<±1%
0.11~0.23
±8μL
<±1%
1ml
0.13~0.26
±8μL
<±0.8%
0.13~0.26
±8μL
<±0.8%
0.08~0.17
±13μL
<±1.3%
3ml
0.25~0.5
±13μL
<±0.6%

MLP10000

Filling Range
Filling Time
Error Value
Accuracy Error
12 Hours Attenuation Rate
100μl
0.15~0.3
±1μL
<±1%

<1%

200μ
0.25~0.5
±1μL
<±0.5%
300μl
0.4~0.8
±1μL
<±0.3%
500μl
0.2~0.4
±5μL
<±1%
1ml
0.17~0.35
±8μL
<±0.8%
0.1~0.2
±13μL
<±1.3%
3ml
0.3~0.6
±13μL
<±0.5%
0.2~0.4
±20μL
<±0.6%
5ml
0.35~0.7
±20μL
<±0.4%
2%
10ml
0.5~1
±40μL
<±0.4%
2%

Dimension        UN(mm)

MLP500

MLP3000

MLP10000

Video:https://youtu.be/wGw4Ty9U6dA

Video