Skip to content
Home » Shop » Z350A2FT1505 ODM Peristaltic Pump

Z350A2FT1505 ODM Peristaltic Pump

Flow: ≤360mL/min
Max: 1 Channel

Peristaltic Pump Introduction

•Combines performance, operation, and practicality;
•The product is designed with a compact structure and small size, offering a larger flow rate compared to other products of the same dimensions.
•Using a flip-cover structure, it provides the maximum tubing space within limited dimensions;
•Convenient tube installation, automatic positioning and tensioning of the tube after installation, no repeated adjustments required;
•Spring pressure block design, maintaining good pressure performance and good tube suitability;
•The device features an observation window, enabling a clear view of the pump head in operation;
•The main body is constructed from reinforced nylon, ensuring strength and durability;
•Pulse stability;

Application

•Compact in size, making it particularly suitable for locations with limited space;
•Precise measurement and transmission of flow, with an emphasis on small flow rates;
•Easy to integrate in OEM setups.

Function and Features

• The drive motor is directly connected to the pump head, making installation and use very convenient.
• The outer shell is made from reinforced nylon, while the roller is crafted from PET material.
• With high corrosion resistance, the performance is reliable.
• Flip cover design, easy to use and quick, saves operating space,
• Replacing the tube is easy and straightforward, and the versatile tube clamp can adapt to different tube sizes.
• The clamp’s position can be adjusted and switched to fit various tube specifications, ensuring it meets different installation needs.

Pump Parameters

Motor Types DC reduction motor
Control and Drive Methods User-supplied
Speed 390rpm
Max Flow Rate 360mL/min
Speed Error ±10%
Working Power Supply DC 24V
Power <10W
Channel Number 1 Channel
Roller Number 4 Roller
Running Direction Clockwise/Counterclockwise rotation
Suitable Tube Wall Thickness 1.6 mm
Suitable Tube Specifications 120#, 13#, 14#, 19#, 16#, 25#
Tube Material Silicone tube, Pharmed
Tube installation method Adaptive tube clamps
Types of Tube Pressure Elastic Gap
Material of the Pump Head Shell Enhancing Nylon
Material of Pump Head Roller Roller: PET; Metal parts: 304
Noise ≤ 60db (testing environment noise ≤40dB, horizontal distance between test product and noise meter is 1 meter)
Dimensions 64mm×64mm×136mm
Working environment Temperature 0- 40°C, , Relative humidity< 85% RH
Storage Environment In a clean and well-ventilated environment with ambient temperatures ranging from -40 to +50°C, and relative humidity not exceeding 95%, the air must not contain corrosive, flammable gases, oil mist, or dust.

Tube Model and Flow Reference Table

Tube Specification Speed mL/rpm 390rpm
Pharmed 120# 0.02 8
13# 0.04 16
14# 0.14 55
19# 0.29 113
16# 0.5 195
25# 0.92 360

The above flow data were all tested using a Lead Fluid silicone tube to pump pure water under laboratory conditions with normal temperature and pressure. This data is for reference only.Due to pressure in actual use , temperature, medium characteristics, tube material and other specific factors,the specific situation needs to consult our engineers.

Head Pump Structure

Component name and function:
1.Active Front Cover: Flipping open or closing the active front cover allows access to the pump head tube compartment;
2.Observation window: For viewing the rotation state of the pump head;
3.The main body: used for motor installation and providing overall machine installation positions;
4.Support: used to support the pump head core;
5.Pump head core: As the working part of the squeeze tube;
6.Position of Tube Clamp: Indicates the current position of the tube clamp;
7.Motors: Provide power.

Figure 1 Products Structure

Figure2 Pump Head Installation Diagram

Usage Method
Step 1: According to the direction shown in the figure, embed the motor into the device, and use 2 pieces M4 pan head screws or hexagon socket screws to fix the pump head onto the device at the mounting hole position.
Step 2: Open the front cover of the activity until it is fully open;
Step 3: Form a tube installation space between the active front cover and the pump head core, and place the tube in this space; straighten the tube inside the pump head, ensuring that it is naturally extended, without twisting or misalignment.
Step 4: Snap the moveable front shell downward until you hear a click. This indicates that the front shell is locked in place, the track has automatically closed, and the tube has been stretched and secured during this process.

Figure 3 Tubes Installation Process Diagram

Dimension(mm)

Note: The motor length might slightly change due to speed parameters. Always refer to the actual length as the standard; the dimensions shown in the figure are only for reference.