Lead Fluid DMD25-T peristaltic pump head mainly meets higher requirements such as high precision filling and large flow and low pulsation. The overall uses of aluminum alloy and SS304 material, excellent mechanical properties.

Flow: 0.058~4200mL/min

Lead Fluid DMD25-Tperistaltic pump head flow range 0.58~4200mL/min, It mainly meets higher requirements such as high precision filling and large flow and low pulsation.

 The transmission smoothness is greatly improved by the double line pulsation complementary method.

 Elastic upper block structure reduces flow attenuation rate and greatly prolongs the service life of pump tube.

Three pump heads can cascade to form three channels,increase productivity.

The overall uses of aluminum alloy and SS304 material, excellent mechanical properties.

Pump Head Material

Shell
Aluminum alloy
Roller
SS304
Roller Axis
SS304
upper block
Aluminum alloy

Flow Rate Parameters

Tube material : Silicone, Pharmed, Viton, Norprene A-60-G/F     Wall thickness 2.4mm
ID(mm)
1.6
2.4
3.2 4.8
6.4
7.9
9.6
Tube
114#
119#
116#
15#
24#
35#
36#
mL/rpm
0.58
1.2
2.1
4.0
7.0
9.0
12.0
mL/min (continuous working maximum 350rpm)
201
426
752
1400
2450
3150
4200

The above flow data wer e obtained from the tests using a silicone tube to transfer pure water
under normal temperature and pressure conditions in the Leif labor atory. This data is f or
reference only.

Tube Installation

Specifications

Speed Range
0.1~350rpm
Flow Range
0.058~4200mL/min
Tube
114#,119#,116#,15#,24#,35#,36#
Channel
1
Roller
6
Pressure tube Structure
Elastic self-adaptation
Transmission Pressure
≤0.12MPa
Dimension
187x105x125mm
Net Weight
2.8kg

Pulsation Complementare Schematic Diagram

Pulsation Curve Simulation Diagram

When DMD25 is an A+B dual pipeline, under the same environmenta l conditions, compare the flow pulsation curve of the mixed pipeline with that of a single pipeline with the same flow rate.

Dimension

 

Tube Lifetime Comparision Table

Notes:
The above data are all test results obtained by Lead Fluid laboratory under normal temperature and
pressure for the transmission of pure water, which are for reference only; the actual service life may
be affected by specific factors such as pressure, temperature, medium characteristics, tube batch
and wall thickness; for specific problems, please contact Lead Fluid engineers to get better technical support.
Statement:The final explanation right of above information belongs to Lead Fluid.