Skip to content
Home » Company News » Analysis and Selection Guide for Peristaltic Pump Housing Materials
Home » Company News » Analysis and Selection Guide for Peristaltic Pump Housing Materials

Analysis and Selection Guide for Peristaltic Pump Housing Materials

  • by

Peristaltic pumps, as precision fluid transfer devices, have their housing materials directly affecting equipment durability, hygiene, and environmental adaptability. This article provides a professional analysis of three common housing materials – PPS plastic, stainless steel, and aluminum alloy – offering selection references for medical, food, and industrial applications.

1.PPS (Polyphenylene Sulfide) Material

Key Advantages:

  • Chemical Stability: Resistant to acids, alkalis, organic solvents, and disinfectants (e.g., alcohol, hydrogen peroxide)
  • High Temperature Resistance: Continuous operating temperature up to 200°C, suitable for sterilization environments
  • Lightweight Design: Specific gravity of 1.35g/cm³, over 60% lighter than metal materials
  • Electrical Insulation: Completely non-conductive, eliminating electromagnetic interference

Medical Applications:

  • Supporting pumps for in vitro diagnostic equipment
  • Disinfectant delivery systems in operating rooms
  • Mobile medical equipment (weight-sensitive scenarios)

Limitations:

  • Impact strength lower than metals
  • Potential aging under prolonged UV exposure
  1. Stainless Steel (Commonly 304/316L)

Core Characteristics:

  • Hygienic Grade: 316L stainless steel complies with GMP Class III certification
  • Mechanical Strength: Compression resistance exceeding 500MPa
  • Corrosion Resistance: Molybdenum content in 316L resists high-chloride environments like physiological saline
  • Surface Treatment: Capable of electropolishing (Ra≤0.4μm)

Typical Applications:

  • Cleanrooms in pharmaceutical industry
  • Corrosive chemical reagent transfer
  • Surgical equipment requiring autoclaving

Considerations:

  • Heavy weight (density 7.9g/cm³)
  • Avoid prolonged contact with halide ions
  1. Aluminum Alloy Material

Performance Features:

  • Weight Advantage: Density of 2.7g/cm³, the lightest metal option
  • Thermal Conductivity: Thermal conductivity of 237W/(m·K), ideal for high-power motor heat dissipation
  • Surface Treatment: Anodized layers up to 25μm enhance corrosion resistance
  • Cost Efficiency: Approximately 40% the cost of stainless steel

Suitable Environments:

  • Housings for portable medical devices
  • Industrial pumps in non-corrosive environments
  • Precision instruments requiring EMI shielding

Usage Restrictions:

  • Not resistant to strong acids/alkalis
  • Relatively low surface hardness (HV80-120)

Selection Principles:

  • Prioritize 316L stainless steel for strict sterilization environments
  • Consider PPS or aluminum for weight-sensitive scenarios
  • Recommend PPS for cost-effective solutions in standard medical equipment
  • Mandatory material compatibility testing for special chemical environments